#Profibus_DP ; ; Control Concepts Profibus uses the UNIGATE IC ; This GSD-File must be used for all UNIGATE (module and IC) with Ident-Nr.3218H ; and Firmware V6.0 and higher. ; These Units support DPV0, DPV1 and Publisher-Support of DPV2 ; ; History: ; ========= ; V0.2 22.12.2014 First Test Release Fusion Version (82, 9) ; V0.3 29.12.2014 Added modules for the Connect (121, 12) ; V0.4 22.01.2015 Removed unused modules; Renamed remaining modules ; V0.5 12.03.2015 Added line continuation on line 111 ; V0.6 12.03.2015 shortened line 113, Changed Max to 1 module ; V0.7 13.03.2015 shortened string descr on line 114 ; V0.8 08.04.2015 Added Module ID numbers ; ; GSD_Revision = 3 ;GSD_Revision = 5 ;Ident_Maintenance_supp = 1 ; Vendor_Name = "Control Concepts Inc" Model_Name = "Connect/Fusion" Revision = "V0.8" Ident_Number = 0x3218 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "Revision H" Software_Release = "V6.0" OrderNumber = "V3218" ; 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 15 MaxTsdr_19.2 = 15 MaxTsdr_45.45 = 15 MaxTsdr_93.75 = 15 MaxTsdr_187.5 = 15 MaxTsdr_500 = 15 MaxTsdr_1.5M = 20 MaxTsdr_3M = 35 MaxTsdr_6M = 50 MaxTsdr_12M = 95 ; Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 Implementation_Type = "VPC3+B" Bitmap_Device = "DAGW" ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 1 Publisher_supp = 1 ;data transfer to other salves possible (DPV2-publisher) ; Modular_Station = 1 Max_Module = 1 Max_Input_Len = 244 Max_Output_Len = 244 Max_Data_Len = 488 Modul_Offset = 0 ; Fail_Safe = 0 Slave_Family = 9 Max_Diag_Data_Len = 11 ; DPV1_Slave = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 80 ;excluding function_num, slot_number, index, length C1_Response_Timeout = 300 Max_Initiate_PDU_Length = 52 C2_Read_Write_supp = 1 C2_Max_Data_Len = 80 ;excluding function_num, slot_number, index, length C2_Response_Timeout = 300 C2_Read_Write_required = 1 C2_Max_Count_Channels = 2 ; DPV1_Data_Types = 0 ; Max_User_Prm_Data_Len = 237 ;depending from used Hardware (9..237) ; PrmText=1 Text(0)="disabled" Text(1)="enabled" EndPrmText ExtUserPrmData=1 "DPV1mode" Bit(7) 0 0-1 Prm_Text_Ref=1 EndExtUserPrmData Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00 Ext_User_Prm_Data_Ref(0) = 1 ; ; ; Module Selection 1 Module = "(Fusion) 82 Word In, 9 Word Out" 0xDF,0xDF,0xDF,0xDF,0xDF,0xD1,0xE8 1 EndModule ; Module Selection 2 Module = "(Connect) 121 Wd In, 12 Wd Out" 0xDF,0xDF,0xDF,0xDF,0xDF,0xDF,0xDF,0xD8,0xEB 2 EndModule ;